Line 25: Line 25:
 periodic calculation (based on a single motive) where the far field is evaluated from three periodic calculation (based on a single motive) where the far field is evaluated from three
 and nine virtual repetitions are then compared to the case where the calculation is not periodic and nine virtual repetitions are then compared to the case where the calculation is not periodic
-and three apertures are physically existing in the computational domain. ​+and three apertures are physically existing in the computational domain. ​The schematics of 
 +the calculations is here: 
 + 
 +{{:​docs:​schematics.png?​600|}}
  
 An important message is that An important message is that
Line 43: Line 46:
 however it is still unclear if this is the only effect. The backup files for this calculation are {{ :​docs:​2d_transmission_aperture_backup_files.tar.gz |here}}.// however it is still unclear if this is the only effect. The backup files for this calculation are {{ :​docs:​2d_transmission_aperture_backup_files.tar.gz |here}}.//
  
 +Accuracy aspects (evaluated on the single aperture transmission): ​
 +   * effect of time step is small, prolonging it from dt=0.5 Courant limit to 0.25 does not change the shape of the curve in a detectable way.
 +   * effect of absorbing boundary type smaller or distance to the boundary much smaller (mostly invisible, below percent?). The transmission around zero order is larger slightly when Liao condition is used instead of CPML. 
 +   * effect of NFFF box size is up to 6 percent for the maximum difference of intensities at the first diffraction order (NFFF box sizes from 100x20 to 340x130, when y size is evaluated from the aperture plane and even for maximum NFFF the boundary in x is about 200 voxels far). Smaller NFFF box seems to be better; when it is enlarged artefacts can be seen. There is always a difference between analytical model that does not go to zero for maximum angles, and numerical model that goes to almost zero.
  
 ---- ----
Line 72: Line 79:
    * default metal setting: 6 0.89583 0 13.8737e15 0.0207332e15 1.3735 -0.504659 7.59914e15 4.28431e15 0.304478 -1.48944 6.15009e15 0.659262e15 means n=(0.036 + 4.147i) and leads to first order diffraction of 0.178    * default metal setting: 6 0.89583 0 13.8737e15 0.0207332e15 1.3735 -0.504659 7.59914e15 4.28431e15 0.304478 -1.48944 6.15009e15 0.659262e15 means n=(0.036 + 4.147i) and leads to first order diffraction of 0.178
  
-Dependence ​on problem ​size:+ 
 +After improving nearly everything (CPML, periodic borders, source) the result is even worse, 0.148 for the fitted metal, spacing 10 nm. However, now the result is fully symmetric and does not depend ​on voxel size (0.147 for spacing 5 nm).
  
  